THE 2-MINUTE RULE FOR DP50RB

The 2-Minute Rule for Dp50rb

The 2-Minute Rule for Dp50rb

Blog Article

Learn improved diagnostic info through extended view of the anatomical framework on all convex probes.

iZoom™ permits exact viewing of impression from length iWorks™ Protocol allows standardize workflow and decrease Test times

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

Notice: Guantee that you could pull out and drive in to the IO board sockets vertically when pulling out and assembling the IO board assembly on the posture from the handle. Clear away panhead screws with washers M3X6 (4) utilized to protected the IO board, after which you can you could possibly consider out the IO board. Website page 116 Get rid of panhead screws with washers (2 M3X6) which might be set on the most crucial unit, choose out the higher baffle and after that pull out two cables connecting the principle board to the power module assembly.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Operate: To the back-finish of the main board, a Unique check IC is utilised to watch sign voltages  and clock battery energy which are furnished to the most crucial board by the key device box electricity provide module.

Efficiency Exam five.5.1 Test Procedure Resolution Detection depth Geometric Place Accuracy Blackout area examination Document the Test images five.5.two Test Material The graphic utilised here is just for reference, persist with the impression effect in the real Be aware: condition. Specifications: Screen: set the contrast and brightness in the clinical software benefit (or maybe the default standing) Operation surroundings: dark room, simulating the clinical software surroundings. Web site seventy six In issue which the transverse resolution testing targets are horizontally exhibited, report the small length of two targets which might be clearly identified. Repeat the operation above with the transverse resolution testing targets at other depths. As revealed in figure below. Axial resolution ... Webpage seventy seven When using the convex probe, preserve the transverse resolution screening targets to NOTE: be exhibited near the midline. When using a linear probe with steer functionality, tend not to turn on the steer operate when accomplish the transverse resolution examination. Zoom within the area where by the targets located if essential. The diameter on the target issue at a certain depth is equal to the transverse resolution at the depth. Page 78 five.

Learn much better diagnostic information and facts by extended check out of the anatomical structure on all linear probes

Cookies Dp50rb login are essential to the correct working of a web-site. To boost your experience, we use cookies to recollect log-in information and provide secure log-in, collect stats to enhance internet site features, and supply information customized towards your pursuits.

Assist 4D probe; figure out the probe through the ID code; switch the 4D push sign through the  electrical relay to generate the 4D probe function normally. four.2.2 Major board The main board might be divided into two parts: front-end of the leading board and back again-end of the key board.

Any time you cease the scanning as well as the graphic capture, it is best to electricity off the technique and disconnect the program within the AC power supply, then pull out AC electricity cables. Page 109: Battery Connecting Board

Mindray’s new era of black & white ultrasound technique, DP-50 Expert, is supplied with State-of-the-art imaging technologies permitting further penetration and more quickly image acquisition with bigger resolution.

probe. The impression abnormality can be brought on by Substitute the probe, or even the swivel in the 4D probe or even the 4D drive switch the 4D travel board board.

Your Device for further biopsy: allowing changes for the scan line to get greater visibility from the needle, nerves and smaller vessels, guaranteeing the continuity of all knowledge.

Report this page